Starter TeSys H 0,75kW-400V control 110-230VAC. range: TeSys - product name: TeSys H - device short name: LZ1H - product or component type: ultra-compact starter - poles description: 3P - [Ie] rated operational current: 2.4 A at 500 V AC-51, 2.4 A at 500 V AC-53A mounting side by side, 2.4 A at 500 V AC-53A, 2.4 A at 500 V AC-51 mounting side by side - motor power kW: 0.37 kW at 220 V AC with power factor : 0.65, 0.37 kW at 230 V AC with power factor : 0.65, 0.75 kW at 380 V AC with power factor : 0.65, 0.75 kW at 415 V AC with power factor : 0.65, 1.1 kW at 500 V AC with power factor : 0.65, 0.75 kW at 400 V AC with power factor : 0.65, 0.75 kW at 440 V AC with power factor : 0.65 - motor power hp: 0.5 hp at 230 V AC, 1 hp at 460 V AC, 0.5 hp at 200 V AC. Benefits: - Up to 75% space reduction, which makes it suitable for all control cabinets where saving space is a priority;, 60% reduction of installation time, thanks to the efficiency of having embedded functions in one slim body;, SIL3/Ple Safe Torque Off variant, simplies design of your safety architecture, A long electrical life, can perform 30million AC53a electrical cycles which make it reliable for high demanding applications.. Applications: TeSys H can be used in a variety of industries, including food and beverage, logistics, and durable goods. It's suitable for machines like conveyors, logistics systems and feeding systems of production machines..
Ambient temperature, , upper operating limit | 70 °C |
---|---|
Degree of protection (IP) | IP20 |
Kind of motor starter | Direct starter |
Overload release current setting | 0.18 A |
Rail mounting possible | Yes |
Rated control supply voltage Us at AC 50HZ | 110 V |
Rated control supply voltage Us at AC 60HZ | 110 V |
Rated operation current Ie | 2.4 A |
Rated operation current at AC-3, 400 V | 2.4 A |
Rated operation power at AC-3, 230 V, 3-phase | 0.37 kW |
Rated operation power at AC-3, 400 V | 0.75 kW |
Rated power, 460 V, 60 Hz, 3-phase | 0.75 kW |
Release class | CLASS 10 |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for ASI | No |
Supporting protocol for CAN | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for LON | No |
Supporting protocol for MODBUS | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SERCOS | No |
Supporting protocol for SUCONET | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for TCP/IP | No |
Supporting protocol for other bus systems | No |
Temperature compensated overload protection | Yes |
Type of electrical connection for auxiliary- and control current circuit | Screw connection |
Type of electrical connection of main circuit | Screw connection |
Voltage type for actuating | AC |
With short-circuit release | No |
UOM | Each |
Category | Motor |